How Much Does a Heat Pump Cost to Run Per Month?
Operating cost comes down to three numbers: your heating load, your system's seasonal COP and your electricity rate. Here's the formula, a worked example, and honest fuel comparisons.
Most homes land between $60 and $450 a month for heat
What a heat pump costs to run comes down to three numbers: how much heat your house needs, how efficiently the unit makes it, and what your utility charges per kilowatt-hour. Change any one of them and the bill moves.
A typical US home spends roughly $60 to $180 a month on heat pump heating in a mild winter month and roughly $150 to $450 in the coldest month of a cold-climate winter, at an electricity rate near 18 cents per kWh.
You can calculate your own figure in about two minutes with one formula. Take your home’s annual heating load in BTU, divide it by 3,412 to get kilowatt-hours of heat, divide that by the system’s seasonal COP, and multiply by your electricity rate. Everything else in this guide is about getting those three inputs right. 💡
This guide is about what a heat pump costs to run, month by month. It is not about what one costs to buy — we cover purchase and installation separately in our 2026 heat pump cost guide, and you can rough out an installed price with the heat pump cost calculator.
Running cost is where most of the confusion lives. People hear “a heat pump is 300% efficient” and expect their bill to fall by two thirds. Then January arrives, the outdoor temperature drops below the unit’s balance point, the backup resistance heat starts running, and the bill goes the other way. Both things are true at once, and the difference between them is worth several hundred dollars a season.
So here is the honest version: the maths, the worked example, a monthly estimate table you can find your house in, a fuel-by-fuel comparison at stated prices, and the handful of levers that genuinely move the number.
What’s in this guide
- The formula, written out
- A worked example, start to finish
- Why COP and HSPF2 beat SEER2 for winter bills
- What happens to cost as it gets colder
- Auxiliary heat: the shocking-January-bill machine
- Monthly cost estimates by home size and climate
- Against gas, propane, oil and resistance heat
- Your electricity rate matters more than your equipment
- Time-of-use tariffs and what they change
- The levers that actually lower the bill
- 6 mistakes that inflate running cost
- Frequently asked questions
- Your running-cost checklist
Alt text: “Homeowner working out heat pump running cost from an electricity bill at a kitchen table”
The formula, written out
There is one equation underneath every heat pump running-cost estimate you will ever read. It looks like this:
Step 1 — heat needed, in kWh: annual heating load (BTU) ÷ 3,412
Step 2 — electricity needed, in kWh: that result ÷ seasonal COP
Step 3 — cost: that result × your electricity rate ($ per kWh)
Written as one line: annual kWh ≈ (heating load in BTU ÷ 3,412) ÷ COP, then multiply by your rate.
The 3,412 is not arbitrary. One kilowatt-hour of electricity contains 3,412 BTU of energy. That is a physical constant, not an efficiency rating. It is the conversion that lets you move between the unit heating equipment is sold in (BTU per hour) and the unit your utility bills in (kilowatt-hours).
The COP — coefficient of performance — is the multiplier that makes a heat pump interesting. A COP of 3.0 means the unit delivers three units of heat for every one unit of electricity it draws. It is not creating energy; it is moving heat that already exists in the outdoor air into your house, and moving is far cheaper than making. Electric baseboard heat has a COP of exactly 1.0. That is the whole story of why heat pumps exist.
The word that does the heavy lifting is seasonal. A single COP figure from a spec sheet is measured at one outdoor temperature, usually 47°F. Your winter is not 47°F all the way through. What you want in this formula is a seasonal average COP that reflects your actual climate, which is a lower and less flattering number than the one on the brochure.
The last input, your electricity rate, is the one people most often get wrong. Do not use the “energy charge” line alone. Take the total dollar amount of a recent bill and divide it by the kilowatt-hours used on that same bill. That all-in figure includes delivery, transmission, riders and taxes, and it is frequently 30% to 60% higher than the headline supply rate. It is the number your money actually leaves at.
Find last month’s electricity bill. Divide the total amount due by the total kWh listed. That is your effective rate. Write it down — you will use it in every calculation on this page, and it is far more accurate than any state average.
A worked example, start to finish
Take a 2,000 square foot house in a moderate climate — think Kansas City, Nashville, southern Ohio, roughly IECC climate zone 4. Reasonably insulated, built in the 1990s, now heated by a modern variable-speed air-source heat pump.
Input 1: the annual heating load. For a home like this, the heat that actually has to be delivered over a heating season commonly lands around 50 million BTU. That number comes from a Manual J load calculation combined with local heating degree days — the same arithmetic behind our heat pump sizing guide. If you have had a load calculation done, use its numbers. If you have not, an estimate is fine for this purpose.
Input 2: convert to kWh of heat. 50,000,000 ÷ 3,412 = 14,654 kWh of heat that has to end up inside the house over the season.
Input 3: divide by the seasonal COP. In a zone 4 climate, a good modern inverter heat pump plausibly averages a seasonal COP around 3.0 once you account for cold days, defrost cycles and a little backup heat. So 14,654 ÷ 3.0 = 4,885 kWh of electricity for the season.
Input 4: multiply by the rate. At 18 cents per kWh, 4,885 × $0.18 = about $880 for the heating season.
Now spread that over the calendar, because this is where the monthly number comes from. Heating load is not distributed evenly. In a zone 4 winter, October and April are small, and January alone typically accounts for something like 20% to 28% of the whole season. Take 25% of 4,885 kWh and you get roughly 1,220 kWh in January, or about $220 for that one month, against maybe $60 in October.
That gap is normal and it is not a fault. It is also why an annual average monthly figure is close to useless when you are trying to predict whether you can afford February.
An annual average tells you what you will spend. The January number tells you whether you will panic.
— why we quote peak-month costs, not averages
The $880 is heating only. Your bill also carries hot water, cooking, lighting, laundry, electronics and, in a lot of homes, a fixed monthly customer charge. If you switched from gas heat to a heat pump, the electric bill goes up by roughly the heating amount while the gas bill drops to just the standing charge and any remaining gas appliances. Compare totals across both fuels, not one bill in isolation.
Why COP and HSPF2 beat SEER2 for winter bills
Every heat pump carries three efficiency ratings, and homeowners routinely shop on the wrong one. Here is what each actually predicts, and we go deeper on all three in SEER2, HSPF2 and COP explained.
SEER2 is a cooling number. It describes how efficiently the unit runs air conditioning across a cooling season. A 20 SEER2 unit will have a lower summer bill than a 15 SEER2 unit. It tells you almost nothing about January. Manufacturers lead with it because it is the biggest, most impressive-looking figure on the label, and because for decades the industry sold cooling first.
HSPF2 is the heating equivalent — a seasonal heating efficiency rating in BTU of heat delivered per watt-hour of electricity consumed. This is the number that predicts your winter bill. It bakes in cold-weather derating, defrost cycles and, importantly, an allowance for backup resistance heat. Current residential ducted equipment generally sits somewhere between about 7.5 and 10+ HSPF2, with ductless mini-splits often rated higher.
COP is an instantaneous measurement at one specific outdoor temperature. It is the most useful number of the three if you can find a full table of it, because it shows you the shape of the performance curve rather than a single blended average.
There is a simple conversion that makes HSPF2 usable in the formula above:
Seasonal COP ≈ HSPF2 ÷ 3.412
An 8.5 HSPF2 unit works out to a seasonal COP of about 2.5. A 10.0 HSPF2 unit is about 2.9. Both are lower than the 3.5 or 4.0 COP quoted at 47°F, and that is exactly the point — the seasonal figure is the honest one.
One important caveat. HSPF2 is measured against a standard regional climate profile, not yours. If you live somewhere much colder than the test region, your real-world seasonal COP will come in below what HSPF2 implies. If you live somewhere much milder, it can come in above. For cold-climate buyers, the more useful data is the manufacturer’s rated capacity and COP at 17°F and 5°F, which is the basis of our cold-climate heat pump roundup.
What happens to cost as it gets colder
A heat pump gets worse at its job as the outdoor temperature falls, and it does so in two ways at once. It delivers less heat, and it uses more electricity per unit of heat delivered. Meanwhile, your house needs more heat. Three curves moving the wrong way together.
The table below shows the general shape for a modern cold-climate inverter unit, using manufacturer-rated performance as the reference. Treat these as illustrative ranges, not a spec for any one model — every unit has its own curve, and published data varies widely by brand and capacity.
| Outdoor temp | Typical rated COP range | Cost per 1 million BTU of heat at 18¢/kWh | What it feels like on the bill |
|---|---|---|---|
| 47°F | 3.5 – 4.5 | $12 – $15 | Very cheap heat |
| 35°F | 3.0 – 3.5 | $15 – $18 | Still comfortably beating most fuels |
| 25°F | 2.5 – 3.0 | $18 – $21 | Roughly level with cheap natural gas |
| 17°F | 2.0 – 2.5 | $21 – $26 | Noticeably more expensive per BTU |
| 5°F | 1.7 – 2.1 | $25 – $31 | Similar to propane or oil |
| -5°F | 1.4 – 1.8 | $29 – $38 | Expensive, but still ahead of resistance heat |
| Backup resistance strips | 1.0 | ~$53 | The number that ruins a month |
Estimates only. Assumes 18¢/kWh all-in. Manufacturer-rated performance varies substantially between models; check the specific unit’s published data.
Read the last two rows together, because that comparison is the single most useful thing on this page. Even at minus 5°F, a working heat pump is still delivering heat for roughly a third less than electric resistance strips. The problem is never that a heat pump becomes worse than baseboard heat. The problem is when the heat pump stops carrying the load and the strips take over.
There is also a defrost penalty that does not show up in a simple COP number. When outdoor humidity and temperature line up in the roughly 25°F to 40°F band, frost builds on the outdoor coil and the unit periodically reverses to melt it, often firing backup heat to keep supply air from going cold. Those cycles are normal — we cover what is normal and what is not in why heat pumps ice up — but they cost real energy, and they are a big reason seasonal COP undershoots spec-sheet COP.
Auxiliary heat: the shocking-January-bill machine
If you get one thing from this guide, get this one. Almost every horror story about a heat pump bill — the $600 January, the “it tripled overnight” post — traces back to auxiliary electric resistance heat running far more than it should.
Auxiliary heat is a bank of electric resistance elements, typically somewhere between 5 and 20 kilowatts, sitting in the air handler. They exist as backup for the coldest hours of the year and for defrost cycles. Their COP is 1.0. Running a 15 kW strip for one hour costs 15 kWh, or $2.70 at 18 cents. Run it eight hours a day for a week and you have added roughly $150 to the month without touching the thermostat again.
Here is the thing that catches people out: auxiliary heat is triggered by control logic, not by physics. The compressor did not fail. The thermostat simply decided the room was too far below setpoint and closed the gap the fast, expensive way. Common triggers include:
A deep overnight setback
Drop the house 8°F at night and the morning recovery is a wide gap. Most thermostats bring on aux once indoor temperature is roughly 2°F below setpoint. You saved a little overnight and handed it all back at 6 a.m. Our thermostat settings guide covers the safe setback range.
No outdoor aux lockout configured
Many thermostats can be told “never use strips above 35°F.” If nobody set that, the strips are free to run on a 45°F day when the compressor could easily have handled it alone.
Emergency heat left switched on
Emergency heat locks out the compressor entirely and runs on strips alone. People flip it on during a cold snap and forget. See emergency heat versus auxiliary heat.
An undersized or badly matched system
If the heat pump cannot carry the load at 30°F, aux is not a backup — it is a co-heater running most of the winter. This is a design problem, not a settings problem.
A dirty filter or blocked coil
Restricted airflow reduces delivered capacity, which widens the gap, which calls aux. A $15 filter can be worth $100 a month.
Nearly every heat pump thermostat displays “AUX” or “Aux Heat” when the strips are energized. Check it a few times a day for a week, including first thing in the morning. If it is on when it is above freezing outside and the house is at setpoint, something is wrong with the settings, the airflow or the equipment — and it is costing you money right now. Smart thermostats with usage history make this even easier: look for the aux runtime hours.
The fix is usually free. Flatten the thermostat schedule, enable adaptive or smart recovery so the system starts climbing early at low speed, and set an outdoor lockout temperature for aux. On a lot of homes, those three changes alone are worth $50 to $150 in a cold month.
Monthly cost estimates by home size and climate
This is the table people come here for, so read the caveats first. These figures are estimates for the coldest month of the year — think January — covering heating only. They assume an electricity rate of 18 cents per kWh all-in, a reasonably insulated home, correct sizing, and a system that is not leaning on auxiliary heat. They do not include hot water, cooking, lighting or the utility’s fixed monthly charge.
| Home size | Mild (zones 2–3) Atlanta, Dallas, coastal CA | Moderate (zone 4) Nashville, KC, Baltimore | Cold (zones 5–6) Chicago, Denver, Boston | Very cold (zone 7) Minneapolis, Fargo |
|---|---|---|---|---|
| 1,000 sq ft | $50 – $75 | $105 – $150 | $155 – $220 | $220 – $310 |
| 1,500 sq ft | $65 – $95 | $145 – $205 | $210 – $300 | $300 – $425 |
| 2,000 sq ft | $85 – $125 | $180 – $260 | $265 – $380 | $380 – $535 |
| 2,500 sq ft | $100 – $150 | $215 – $310 | $315 – $450 | $450 – $640 |
| 3,000 sq ft | $115 – $170 | $250 – $355 | $365 – $520 | $520 – $735 |
Estimates only. Peak winter month, heating only, at 18¢/kWh. Shoulder months (October, November, March, April) typically run 25% to 50% of these figures. A whole heating season commonly totals three to four times the peak month.
Two adjustments worth making before you use a row. First, scale for your rate: if you pay 12 cents, multiply by 0.67; if you pay 30 cents, multiply by 1.67. Second, scale for your house: a 1970s home with single-pane windows and an uninsulated attic can easily use 50% to 80% more than these figures, while a well-air-sealed home with good windows can come in 20% to 30% under them. Square footage is a proxy for heating load, and a rough one.
If your actual bill is more than about 40% above the relevant range and your rate is close to 18 cents, that is a signal worth chasing. Start with the aux indicator, then the filter, then whether the system is short cycling. If it is running constantly and never reaching setpoint, that is a different problem — see heat pump not heating.
Alt text: “Two homes of different sizes with outdoor heat pump units in winter, illustrating how running cost scales”
Against gas, propane, oil and resistance heat
The only fair way to compare heating fuels is cost to deliver a fixed amount of usable heat. The table below prices one million BTU of heat actually delivered into the house, after equipment efficiency. Every price in it is a stated assumption, not a promise.
The assumed prices: electricity at 18¢/kWh, which is close to the current US residential average; natural gas at $1.50 per therm, which is roughly where the EIA’s residential series has been running when converted from dollars per thousand cubic feet; propane at $2.50 per gallon; heating oil at $3.50 per gallon. Fuel prices swing hard by region and by season, so substitute your own.
| Heat source | Assumed price | Efficiency | Cost per 1 million BTU delivered |
|---|---|---|---|
| Heat pump, mild climate | 18¢/kWh | Seasonal COP 3.5 | ~$15 |
| Natural gas furnace | $1.50/therm | 95% AFUE | ~$16 |
| Heat pump, moderate climate | 18¢/kWh | Seasonal COP 3.0 | ~$18 |
| Heat pump, cold climate | 18¢/kWh | Seasonal COP 2.5 | ~$21 |
| Natural gas furnace | $2.00/therm | 95% AFUE | ~$21 |
| Propane furnace | $2.50/gal | 95% AFUE | ~$29 |
| Oil furnace or boiler | $3.50/gal | 85% AFUE | ~$30 |
| Electric resistance / baseboard | 18¢/kWh | COP 1.0 | ~$53 |
Estimates at the stated prices. Uses 100,000 BTU per therm, 91,500 BTU per gallon of propane and 138,500 BTU per gallon of heating oil.
Now the honest part, and it is the part most heat pump articles skip.
At 18¢/kWh electricity and $1.50/therm gas, a heat pump needs a seasonal COP of roughly 3.3 just to break even with a 95% AFUE gas furnace. In a mild climate that is achievable. In zone 5 or colder, seasonal COP is more often 2.2 to 2.8, which means the heat pump costs more to run than the furnace it replaced — sometimes 15% to 30% more. That is not a reason never to install one, but it is a reason to do the arithmetic before you assume savings. Our heat pump versus furnace comparison works through the trade-offs.
Where a heat pump wins on running cost, it usually wins big. Replacing electric baseboard or an electric furnace typically cuts heating electricity by 50% to 65%, and that is the clearest financial case in the whole category. Replacing propane or oil is also a strong case at the prices above — roughly 30% to 45% lower running cost even at a modest seasonal COP. Replacing cheap natural gas is a coin flip that depends heavily on your local gas and electricity prices.
One structural point in favor of the heat pump that the table cannot show: it also does your cooling. If you were going to replace an aging air conditioner anyway, the heat pump absorbs that cost and that equipment. A furnace does not.
Your electricity rate matters more than your equipment
Upgrading from a mid-tier heat pump to a top-tier one might improve seasonal COP from 2.7 to 3.2 — call it a 15% cut in heating electricity. Moving from Massachusetts to Tennessee would cut your rate by more than half. Geography beats equipment, and there is nothing you can do about geography.
US residential electricity prices in 2026 span an enormous range. National average figures sit somewhere around 18 cents per kWh, but the lowest states are in the low-13-cent range and Hawaii runs well over 50 cents, with several New England states and California toward the upper end. Here is the same worked example from earlier — 4,885 kWh of heating electricity for the season — priced at different rates.
| Your all-in rate | Season heating cost | Peak month estimate | Roughly where |
|---|---|---|---|
| 12¢/kWh | ~$585 | ~$145 | Lower-cost states in the South and Mountain West |
| 15¢/kWh | ~$730 | ~$185 | Much of the Midwest and Southeast |
| 18¢/kWh | ~$880 | ~$220 | Close to the US average |
| 25¢/kWh | ~$1,220 | ~$305 | Parts of the Northeast and West Coast |
| 35¢/kWh | ~$1,710 | ~$425 | High-cost coastal and island markets |
Estimates. Same 50 million BTU heating load and seasonal COP 3.0 in every row; only the rate changes.
Two practical implications. If you are in a low-rate state with expensive delivered fuel — propane country, much of rural America — a heat pump is close to a slam dunk on running cost. If you are in a high-rate state with cheap piped natural gas, run the numbers carefully and consider whether a dual-fuel setup, where a heat pump handles mild weather and a gas furnace takes over below a set outdoor temperature, gives you the better of both.
The other thing worth knowing: in many places, electricity rates have been rising faster than gas rates recently, and utilities are increasingly shifting costs into fixed monthly charges. Both of those move the break-even point. Check what your utility has filed, not what was true three years ago.
A number of utilities offer a discounted winter rate, a separately metered heating rate or a whole-home electrification rate for customers with electric heat. These are easy to miss because they are rarely advertised. Call and ask specifically whether a heating-season or electrification rate exists, and what the enrollment requirements are. Also see what rebates still exist in 2026 — note that the federal 25C tax credit ended for property placed in service after 31 December 2025, so state and utility programs are where the money is now.
Time-of-use tariffs and what they change
Time-of-use pricing charges different rates at different hours. A common shape is a cheap overnight and midday period, a much more expensive block in the late afternoon and evening, and sometimes a distinct winter morning peak from roughly 6 to 9 a.m. Spreads vary, but a peak rate two to three times the off-peak rate is not unusual, and in some markets it is wider.
For a heat pump this cuts both ways. The bad news is that winter heating demand naturally peaks in the early morning and again in the evening, which in many tariffs is precisely when electricity is most expensive. Left alone, a heat pump concentrates its consumption in the worst hours.
The good news is that a house has thermal mass, and you can use it. The strategy is pre-heating: let the system warm the house by an extra degree or two during the cheap window immediately before the peak, then coast. The house drifts down slowly through the expensive hours instead of calling for heat during them.
Do not confuse pre-heating with a deep setback. Raising the setpoint 1 to 2°F before a peak is fine. Letting the house fall 6°F during peak and then demanding it back is the classic way to trigger auxiliary resistance heat, which will cost you far more than the peak rate ever would. Small moves, gradual recovery.
A few practical notes. Most modern smart thermostats can run a time-of-use schedule, and some integrate directly with utility rate plans. Well-insulated, tight homes hold a pre-heat far better than leaky ones, so the strategy is worth more the better your envelope is. And before you enroll in a TOU plan, pull twelve months of hourly usage data from your utility if they offer it — many do — and check what your bill would have been. Some households genuinely lose money on TOU.
Time-of-use rates also change the arithmetic if you have or are considering rooftop solar, because generation lands in the middle of the day. We work through that pairing in detail in pairing a heat pump with solar panels.
The levers that actually lower the bill
Ranked roughly by how much they move the number, for the least money.
Stop the auxiliary heat from running unnecessarily
Free, and the biggest single lever in most homes. Flatten the schedule, cap setbacks at 2 to 4°F, turn on adaptive recovery, and configure an outdoor lockout so the strips cannot run above a set temperature. Confirm emergency heat is off.
Hold a steady setpoint
Also free. Heat pumps are most efficient running long and slow at low compressor speed. Pick a temperature you are comfortable at, hold it, and accept that the furnace playbook does not transfer.
Change the filter on schedule
A few dollars a quarter. Restricted airflow drops delivered capacity, lengthens run times and invites aux heat. Every one to three months for a 1-inch filter, depending on pets and dust. This and the rest of the routine live in our maintenance checklist.
Air-seal the obvious leaks
A weekend and under $100 of caulk, foam and weatherstripping. Attic hatches, rim joists, plumbing and wiring penetrations, and around window and door frames. Reducing the heating load reduces every future bill, permanently, regardless of what equipment you own.
Insulate the attic
Bigger money, but the highest-return envelope upgrade in most US homes, and many utilities subsidize it. An underinsulated attic is why some houses use 60% more than the table above predicts.
Keep the outdoor unit clear
Free. Leaves, grass clippings, snow drifts and shrubs choke airflow across the outdoor coil, which cuts capacity and triggers extra defrost cycles. Give it two feet of clearance and clear snow away from the base after storms.
Look at your rate plan
Free to check. A heating-season rate, an electrification tariff or a time-of-use plan that suits your pattern can be worth more than any equipment upgrade.
Get the system commissioned properly
Costs a service call. Refrigerant charge, airflow, and aux staging set correctly at install can be worth 10% to 20% of heating energy. Refrigerant work requires an EPA-certified technician, and 2025-onward equipment uses A2L refrigerants like R-454B or R-32 that need rated tools and training. This is not a DIY area.
Closing vents in unused rooms raises duct static pressure and usually hurts. Space heaters “to take the load off” are pure COP 1.0 resistance heat and almost always cost more. Turning the thermostat up higher does not heat the house any faster — the thermostat is a switch, not a throttle.
6 mistakes that inflate running cost
❌ Mistake 1: Comparing the new electric bill to the old electric bill
If you replaced a gas furnace, of course the electric bill went up — the heating moved onto it. People see a $200 jump, panic, and never notice the gas bill fell by $180.
❌ Mistake 2: Shopping on SEER2 when the concern is the winter bill
SEER2 is the biggest number on the label and it describes cooling. Two units with identical SEER2 can have meaningfully different heating performance, and in a cold climate that difference is what you will pay for.
❌ Mistake 3: Running a big nightly setback out of furnace habit
Eight degrees down at 10 p.m. and back up at 6 a.m. is standard furnace advice and it is close to the worst thing you can do to a heat pump bill, because recovery pulls in resistance heat at three times the cost.
❌ Mistake 4: Using the supply rate instead of the all-in rate
Estimating with the 9-cent “energy charge” from the bill when delivery, transmission and taxes push the real figure to 19 cents. Every projection built on that number is off by half.
❌ Mistake 5: Assuming an oversized unit will cost less to run
Bigger is not cheaper. An oversized system short cycles, spends more time at inefficient high compressor speeds, dehumidifies poorly in summer and wears out sooner. It also costs more to buy.
❌ Mistake 6: Ignoring the envelope and blaming the equipment
A heat pump in a leaky, underinsulated house will produce an expensive bill no matter how good it is, because the heating load itself is the problem. Replacing a good heat pump with a better heat pump fixes very little.
Frequently asked questions
How much does a heat pump cost to run per month?
For heating only, most US homes land somewhere between about $50 and $170 a month in a mild climate and between about $150 and $550 in the coldest month in a cold climate, at an electricity rate near 18 cents per kWh. Shoulder months are typically a quarter to a half of the peak month. These are estimates — your rate, home size, insulation and thermostat habits move them substantially, so run the formula with your own numbers.
How do I calculate my own running cost?
Take your annual heating load in BTU, divide by 3,412 to convert to kilowatt-hours of heat, divide that by your system’s seasonal COP, then multiply by your all-in electricity rate. If you only know HSPF2, divide it by 3.412 to get an approximate seasonal COP. Use the total-bill-divided-by-total-kWh figure for your rate, not the supply charge.
Is a heat pump cheaper to run than natural gas?
Often, but not always, and the answer depends entirely on local prices. At 18 cents per kWh and $1.50 per therm, a heat pump needs a seasonal COP of about 3.3 just to break even with a 95% AFUE gas furnace. Mild climates can reach that. Cold climates usually cannot, so in zone 5 and colder with cheap gas, the heat pump may cost 15% to 30% more to run. Against propane, oil or electric resistance, the heat pump wins comfortably at the prices assumed in this guide.
Why did my heat pump bill triple in January?
The overwhelmingly common cause is auxiliary electric resistance heat running far more than it should. Those strips have a COP of 1.0, so every hour they run costs roughly three times what the heat pump costs for the same heat. Check whether the thermostat shows AUX during normal operation, whether emergency heat was left switched on, whether your schedule has a deep setback, and whether the filter is clogged.
Does a heat pump cost more to run in very cold weather?
Yes, and for two reasons at once. Efficiency falls as outdoor temperature drops — a unit that manages a COP near 4.0 at 47°F might be nearer 2.0 at 17°F — while the house simultaneously needs more heat. Even so, a working heat pump at 5°F still delivers heat for meaningfully less than electric resistance. The expensive scenario is the strips taking over, not the compressor running hard.
Is it cheaper to leave a heat pump running all day?
In winter, steady operation usually beats deep setbacks, because recovery from a big drop tends to trigger backup resistance heat that costs more than the setback saved. That does not mean running at a higher temperature — it means holding one comfortable temperature rather than swinging it. In summer, when there is no resistance backup involved, normal setback rules apply again.
Will a bigger or more expensive heat pump lower my bill much?
Bigger, no — oversizing generally raises running cost through short cycling. More efficient, somewhat: moving from a mid-tier to a top-tier unit might cut heating electricity by 10% to 20%. That is real, but it is smaller than the effect of your electricity rate, your insulation or your auxiliary heat settings, all of which are cheaper to address.
Your running-cost checklist
✅ Your checklist
- Find your all-in rate — total bill divided by total kWh, not the supply charge
- Run the formula — heating load ÷ 3,412 ÷ seasonal COP × rate
- Convert HSPF2 to seasonal COP — divide by 3.412 for a realistic figure
- Watch the AUX indicator for a week — it explains most surprise bills
- Set an outdoor aux lockout — free, and often the single biggest saving
- Cap winter setbacks at 2–4°F — and flatten the schedule in a cold snap
- Change the filter every 1–3 months — restricted airflow costs real money
- Compare fuels per million BTU — not per therm, gallon or kWh
- Ask your utility about heating or electrification rates — rarely advertised, sometimes worth a lot
- Air-seal and insulate before upgrading equipment — a smaller load lowers every future bill
- Treat every number here as an estimate — substitute your own rate and load before deciding anything
Sources
- EIA — U.S. Price of Natural Gas Delivered to Residential Consumers (annual series)
- EIA — Electric Power Monthly, average retail price of electricity by state (Table 4)
- EIA — Short-Term Energy Outlook (residential fuel price and heating expenditure forecasts)
- U.S. Department of Energy — Heat Pumps
- ENERGY STAR — Air-Source Heat Pumps product criteria (HSPF2 / SEER2 / EER2)